3 | ENGLISH
LED indicator :
Flashes continuously : Motion detector is performing a self-test
Flashes 1x : Motion detected
Flashes 2x : Self-test completed. Motion detector is active
Flash once per 3 seconds : Battery power low, exchange battery*
* You will receive a text message if battery level is low. The message contains the
following information (up to sensor 9) Sensor name with additionally the text ‘battery
almost empty’. From sensor 10 the name will be replaced by a zone nr. with
additionally the text ‘battery almost empty’.
3.0 Inside the motion detector
Remove the screw on top of the motion detector and gently remove the front and
back.
3.1 Infrared sensors
The infrared sensors detect the motion. These sensors need to be clean at all time.
Do no touch the sensors !
3.2 Anti sabotage button
If the motion detector is opened this switch will detect it and trigger the alarm.
3.3 LED On/Off
By switching this jumper setting you can set if the LED in front of the motion detector
will be switched “On or Off. By default this setting is turned ON (LED ON).
3.4 Group settings (jumpers)
Every sensor can be configured to be added to a dedicated group by setting the
jumper settings; home-group, normal group, single group or 24-hours group.
LED On/Off
Infrared sensor
Group setting (jumpers)
Infrared sensor
Vista de página 2
1 2 3 4 5 6 7 8

Comentários a estes Manuais